The paper herein shows modeling and optimization of a continuous-flow ultraviolet/hydrogen peroxide (UV/H2O2) AOP to degrade chemical oxygen demand (COD) in simulated dairy wastewater. The common conventional treatment procedures, such as biological and physicochemical processes, may be limited by the high amount of sludge formation, high costs, and poor removal of recalcitrant organic contaminants that form. This research, therefore, aims to design a more effective photochemical treatment alternative by conducting experimental studies and developing a more accurate model. A tailor-made cubic photoreactor with double 6 W low-pressure UV lamps (254 nm) was used to investigate the effect of three parameters: the flow rate (10,20, and 30 mL/min), hydraulic retention time (HRT; 10 to 240 min), and initial COD concentration (250 to 1000 mg/L). The studies used 1.2 mL/L H2O2, pH 7.5, at a temperature of 25 ºC. Box-Behnken Design (BBD) and Response Surface Methodology (RSM) were employed, and their optimization of the process and predictive modeling yielded a second-order polynomial regression model. The regression model displayed a high degree of statistical significance (R² = 0.954, Adjusted R² = 0.917; p < 0.0001), while the low root-mean-square error (RMSE = 5.41%) further supports the model’s precision and predictive robustness, accounting for 95.4% of the total variance. At optimal conditions (flow rate 10 mL/min, HRT 240 min, and initial COD 250 mg/L), there was a maximum COD removal efficiency of 82.8% as compared to the standard deviation of 0.37. This increased performance was attributed to the prolonged exposure to oxidation and the elevated availability of hydroxyl radicals in the reduced, low-flow, high-retention flow regimes. The system's operational stability was further indicated by the fact that the values had a low standard deviation during steady-state phases.This work demonstrates that it is viable to use UV/H2O2-based AOPs in continuous reactor systems, which offer a sludge-free, scalable, and energy-efficient approach to treating high-strength industrial effluents. The validated model can be effectively used to predict and optimize real-life processes.
References
F. Carvalho, A. R. Prazeres, J. Rivas, Cheese whey wastewater: Characterization and treatment, Sci. Total Environ., 445 (2013) 385–396. https://doi.org/10.1016/j.scitotenv.2012.12.038 Metcalf & Eddy, A.E.C.O.M. Wastewater engineering treatment and resource recovery; McGraw-Hill Education, 2014. B. T. Ibigbami, S. O. Adewuyi, A. M. Akinsorotan, A. A. Sobowale, I. M. Odoh, A. Aladetuyi, Advanced oxidation processes: a supplementary treatment option for recalcitrant organic pollutants in Abattoir wastewater, J. Appl. Res. Technol., 21 (2023) 1019–1041. https://doi.org/10.22201/icat.24486736e.2023.21.6.2212 I. Oller, S. Malato, J. A. Sánchez-Pérez, Combination of advanced oxidation processes and biological treatments for wastewater decontamination—a review, Sci. Total Environ., 409 (2011) 4141–4166. https://doi.org/10.1016/j.scitotenv.2010.08.061 S. Malato, P. Fernández-Ibáñez, M. I. Maldonado, J. Blanco, W. Gernjak, Decontamination and disinfection of water by solar photocatalysis: recent overview and trends, Catal. Today., 147 (2009) 1–59. https://doi.org/10.1016/j.cattod.2009.06.018 H. Chen, M. Yang, C. Huang, Y. Wang, Y. Zhang, M. Zuo, A dynamic model of CO2 diffusion coefficient in shale based on the whole process fitting, Chem. Eng. J., 427 (2022) 131–151. https://doi.org/10.1016/j.cej.2021.131151 M. B. Ahmed, J. L. Zhou, H. H. Ngo, W. Guo, N. S. Thomaidis, J. Xu, Progress in the biological and chemical treatment technologies for emerging contaminant removal from wastewater: A critical review, J. Hazard. Mater., 323 (2017) 274–298. https://doi.org/10.1016/j.jhazmat.2016.04.045 È. Tsabet, and L. Fradette, Study of the properties of oil, particles, and water on particle adsorption dynamics at an oil/water interface using the colloidal probe technique, Chem. Eng. Res. Des., 109 (2016) 307–316. https://doi.org/10.1016/j.cherd.2016.02.001 J. H. Ramírez, L. A. Galeano, G. Pinchao, R. A. Bedoya, and A. Hidalgo, Optimized CWPO phenol oxidation in CSTR reactor catalyzed by Al/Fe-PILC from concentrated precursors at circumneutral pH, J. Environ. Chem. Eng., 6 (2018) 2429–2441. https://doi.org/10.1016/j.jece.2018.02.024 K. C. Wijekoon, C. Visvanathan, and A. Abeynayaka, Effect of organic loading rate on VFA production, organic matter removal and microbial activity of a two-stage thermophilic anaerobic membrane bioreactor, Bioresour. Technol., 102 (2011) 5353–5360. https://doi.org/10.1016/j.biortech.2010.12.081 P. R. Gogate, A. B. Pandit, A review of imperative technologies for wastewater treatment I: Oxidation technologies at ambient conditions, Adv. Environ. Res., 8 (2004) 501–551. https://doi.org/10.1016/S1093-0191(03)00032-7 S. H. Lin, C. C. Lo, Fenton process for treatment of desizing wastewater, Water Research, 31 (1997) 2050–2056. https://doi.org/10.1016/S0043-1354(97)00024-9 S. Lin, J. Kim, C. Hua, S. Kang, and M. H. Park, Comparing artificial and deep neural network models for prediction of coagulant amount and settled water turbidity: lessons learned from big data in water treatment operations, J. Water Proc. Eng., 54 (2023) 103949. https://doi.org/10.1016/j.jwpe.2023.103949 N. A. Z. Azizan, A. Yuzir, and N. Abdullah, Pharmaceutical compounds in anaerobic digestion: A review on the removals and effect to the process performance, J. Environ. Chem. Eng., 9 (2021) 105926. https://doi.org/10.1016/j.jece.2021.105926 V. J. Giglio, O. J. Luiz, and C. E. Ferreira, Ecological impacts and management strategies for recreational diving: A review, J. Environ. Manag., 256 (2020) 109949. https://doi.org/10.1016/j.jenvman.2019.109949 M. A. Bezerra, R. E. Santelli, E. P. Oliveira, L. S. Villar, L. A. Escaleira, Response surface methodology (RSM) as a tool for optimization in analytical chemistry, Talanta, 76 (2008) 965–977. https://doi.org/10.1016/j.talanta.2008.05.019 N. Bilal, Application of advanced oxidations processes for the treatments of textile effluents, Asian J. Chem., 26 (2014). https://doi.org/10.14233/ajchem.2014.14885 G. S. P. Soylu, Z. Özçelik, and İ. Boz, Total oxidation of toluene over metal oxides supported on a natural clinoptilolite-type zeolite, Chem. Eng. J., 162 (2010) 380–387. https://doi.org/10.1016/j.cej.2010.05.020 M. A. Oturan, and J. J. Aaron, Advanced oxidation processes in water/wastewater treatment: principles and applications. A review, Crit. Rev. Environ. Sci. Technol., 44 (2014) 2577–2641. https://doi.org/10.1080/10643389.2013.829765 D. Ma, H. Yi, C. Lai, X. Liu, X. Huo, Z. An, L. Li, Y. Fu, B. Li, M. Zhang, and L. Qin, Critical review of advanced oxidation processes in organic wastewater treatment, Chemosphere, 275 (2021) 130104. https://doi.org/10.1016/j.chemosphere.2021.130104 M. C. Collivignarelli, R. Pedrazzani, S. Sorlini, A. Abbà, and G. Bertanza, H2O2 based oxidation processes for the treatment of real high strength aqueous wastes, Sustainability, 9 (2017) 244. https://doi.org/10.3390/su9020244 B. P. Chaplin, Critical review of electrochemical advanced oxidation processes for water treatment applications, Environ. Sci-Proc. Imp., 16 (2014) 1182–1203. https://doi.org/10.1039/C3EM00679D P. de Abreu, E. L. Pereira, C. M. M. Campos, and F. L. Naves, Photocatalytic Oxidation Process (UV/H2O2/ZnO) in the treatment and sterilization of dairy wastewater, Acta Sci. Technol., 35 (2013) 75–81. Montgomery, D.C., Design and analysis of experiments; John wiley & sons, 2017. R. H. Myers, D. C. Montgomery, Response surface methodology, IIE Transactions, 28 (1996) 1031–1032. https://doi.org/10.1080/15458830.1996.11770760 A. V. Santos, C. F. Couto, Y. A. R. Lebron, V. R. Moreira, A. F. S. Foureaux, E. O. Reis, de Souza, L. V. Santos, L. H. de Andrade, M. C. S. Amaral, and L. C. Lange, Occurrence and risk assessment of pharmaceutically active compounds in water supply systems in Brazil, Sci. Total Environ., 746 (2020) 141011. https://doi.org/10.1016/j.scitotenv.2020.141011 U. Hübner, S. Spahr, H. Lutze, A. Wieland, S. Rüting, W. Gernjak, and J. Wenk, Emerging advanced oxidation processes for water and wastewater treatment–guidance for systematic future research, Environ. Sci. Technol., (2022). https://doi.org/10.31223/X5MH05 A. Giwa, A. Yusuf, H. A. Balogun, N. S. Sambudi, M. R. Bilad, I. Adeyemi, S. Chakraborty, and S. Curcio, Recent advances in advanced oxidation processes for removal of contaminants from water: A comprehensive review, Process. Saf. Environ. Prot., 146 (2021) 220–256. https://doi.org/10.1016/j.psep.2020.08.015
Highlights
A UV/H₂O₂ reactor achieved 82.8% COD removal in dairy effluent under optimal BBD-RSM conditions. Hydraulic retention time was the most influential factor, followed by flow rate and COD concentration. The quadratic model showed high reliability (R² = 0.987) and strong predictive accuracy for process optimization.
Recommended Citation
Hashim, Anwar and Salman, Mohammed
(2025)
"Assessment and surface modeling of COD removal from simulated dairy wastewater in a continuous advanced oxidation reactor,"
Engineering and Technology Journal: Vol. 43:
Iss.
11, Article 16.
DOI: https://doi.org/10.30684/etj.2025.162872.1989
DOI
10.30684/etj.2025.162872.1989
First Page
1023
Last Page
1032